Ø83mm Water Shield – Threaded (FM Approved)
RM14.00
These are threaded water shields designed to create a pendent intermediate level sprinkler when installed on an approved sprinkler. (3-1/4″ [83mm] diameter) water shields are threaded onto 1/2″ sprinkler inlet threads prior to installation.
- Model E1 or E2
- 83mm Diameter Water Shield
- Screw on type: Available in 1/2″(15mm) & 3/4″(20mm) Sprinkler to be used without a guard
- FM approved
Shipping & Delivery
Related products
ABS Plain/Threaded Socket
RM3.70 – RM20.33Price range: RM3.70 through RM20.33
Plain/Threaded Sockets are pipe fitting used to connect either a plain fitting or piece of pipe to a threaded fitting or piece of pipe of the same diameter.
BBB - ABS Pipes & Fittings
F1FR 56: Quick Response Sprinkler (1/2″ Orifice) Chrome
RM53.00 – RM86.00Price range: RM53.00 through RM86.00
Reliable Quick Response Sprinklers are ideal for protecting light and ordinary hazard applications such as office buildings, hotels, schools, and restaurants to control the spread of fire.
RELIABLE - Product Brochure
- Combines the durability of a standard sprinkler with the attractive low profile of a decorative sprinkler
- 3 mm glass bulb
- F1FR Series
| Style | Conventional, Pendent, Upright, Horizontal Sidewall (HSW) |
| K-Factor | 2.8(40), 4.2(60), 5.6(80) |
| Temperature | 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C) |
| Thread Size | 1/2" NPT(R1/2) |
| Escutcheon | F1, F2, FP Push-on/Thread-off, FT |
| Cover Plate | CCP |
| Finish | Brass, Chrome, White Poly Coated, Custom |
J112: Extended Coverage Sprinkler, Chrome (3/4″ NPT)
RM135.00
Reliable Extended Coverage Sprinklers are designed to protect larger areas than specified by installation rules for standard spray sprinklers.
RELIABLE - Product Brochure
- Extended Coverage for both Light and Ordinary Hazard occupancies for coverage areas from 144 ~ 400sqft
- Pendent, Recessed Pendent: Quick Response for Light Hazard - 16"x16" to 20"x20" sprinkler spacing
- Pendent, Recessed Pendent: Quick Response for Ordinary Hazard - 12"x12" & 14"x14" sprinkler spacing
- Standard Response for Ordinary Hazard - 16"x16" to 20"x20" sprinkler spacing
- 3mm glass bulb (J112)
| Style | Pendent, Recessed Pendent, Upright |
| K-Factor | 11.2 (160) |
| Temperature | Pendent: 155°F (68°C) Recessed Pendent: 200°F (93°C) Upright: 200°F (93°C) |
| Thread Size | 3/4" NPT(R3/4) |
| Escutcheon | Pendent, Recessed Pendent: F1, F2, FP Push-on/Thread-off |
| Finish | Bronze, Chrome, White Polyester |
G XLO: Storage Sprinkler (3/4″ NPT) Brass
RM121.00
Reliable Storage Sprinkler Systems are designed to protect the storage of raw materials and components, commodities, or finished goods according to defined commodity classes and the configuration of the storage facility.
RELIABLE - Product Brochure
- Solder fusible link
- Extra large orifice for use in high challenge storage occupancies
- Can operate at pressures as low as 7 psi
- Lower operating pressure saves cost by reducing branch line sizes, fire pump sizes, fewer sprinklers
| Style | Pendent & Upright |
| K-Factor | 11.2 (160) |
| Temperature | 165°F (74°C), 212°F (100°C), 286°F (141°C) |
| Thread Size | 3/4" NPT(R3/4) |
| Finish | Bronze, Chrome, Custom |
HL22 ESFR: Storage Sprinkler – Pendent (1″ NPT)
RM263.00
Reliable Storage Sprinkler Systems are designed to protect the storage of raw materials and components, commodities, or finished goods according to defined commodity classes and the configuration of the storage facility.
RELIABLE - Product Brochure
- Early suppression, fast response sprinkler for the protection of high-piled storage
- Levered fusible alloy solder link available with a 165°F (74°C) or 212°F (100°C) temperature rating Eliminates in-rack sprinkler requirements and is optimized for use in buildings over 40" up to 45" in height
- Maximum ceiling-to-deflector distance is 18" (457mm)
- Lower flow requirements offers opportunities to reduce sizing requirements of system pipe, fire pumps, underground pipe and storage tanks
| Style | ESFR Pendent |
| K-Factor | 22.4 (320) |
| Temperature | 165°F (74°C), 212°F (100°C) |
| Thread Size | 1" NPT(R1) |
| Finish | Bronze |
JL-17 ESFR: Storage Sprinkler – Pendent (3/4″ NPT)
RM149.00
Reliable Storage Sprinkler Systems are designed to protect the storage of raw materials and components, commodities, or finished goods according to defined commodity classes and the configuration of the storage facility.
RELIABLE - Product Brochure
- Early suppression, fast response sprinkler for the protection of high-piled storage
- Levered fusible alloy solder link available with a 165°F (74°C) or a 212°F (100°C) temperature rating
- Delivers approximately 121gpm (458L/min) of water at 52psi (3.6bar)
| Style | ESFR Pendent |
| K-Factor | 16.8 (242) |
| Temperature | 165°F (74°C), 212°F (100°C) |
| Thread Size | 3/4" NPT(R3/4) |
| Finish | Bronze |
G5-56: Dry Concealed Pendent Sprinkler (1/2″ NPT) (W/O Coverplate)
RM82.00
Model G5 series sprinklers are standard coverage, flat plate concealed sprinklers designed for installation in accordance with NFPA 13 and FM Global Property Loss Prevention Data Sheets. All Model G5 series sprinklers use a fusible-link operating element.
- Standard Coverage, Concealed Pendent (K2.8, 4.2, 5.6, & 8.0 [40, 60, 80, & 115 metric])
- Flat concealed cover plate available in a variety of finishes
- Available with Stainless Steel Clad cover plate (see Table I)
- 3/4-inch (19 mm) cover plate adjustment
- Cover plate available with optional gasket
G5 Plain White Cover-Plate (165°F 74°C)
RM41.00
RELIABLE Cover Plates are available in 2 standard finishes: Chrome & White Paint, and 8 special application finishes.
RELIABLE - Product Brochure